Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.589
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(5): 895-905, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38433304

RESUMO

INTRODUCTION: Cardiac contractility modulation (CCM) is a medical device-based therapy delivering non-excitatory electrical stimulations to the heart to enhance cardiac function in heart failure (HF) patients. The lack of human in vitro tools to assess CCM hinders our understanding of CCM mechanisms of action. Here, we introduce a novel chronic (i.e., 2-day) in vitro CCM assay to evaluate the effects of CCM in a human 3D microphysiological system consisting of engineered cardiac tissues (ECTs). METHODS: Cryopreserved human induced pluripotent stem cell-derived cardiomyocytes were used to generate 3D ECTs. The ECTs were cultured, incorporating human primary ventricular cardiac fibroblasts and a fibrin-based gel. Electrical stimulation was applied using two separate pulse generators for the CCM group and control group. Contractile properties and intracellular calcium were measured, and a cardiac gene quantitative PCR screen was conducted. RESULTS: Chronic CCM increased contraction amplitude and duration, enhanced intracellular calcium transient amplitude, and altered gene expression related to HF (i.e., natriuretic peptide B, NPPB) and excitation-contraction coupling (i.e., sodium-calcium exchanger, SLC8). CONCLUSION: These data represent the first study of chronic CCM in a 3D ECT model, providing a nonclinical tool to assess the effects of cardiac electrophysiology medical device signals complementing in vivo animal studies. The methodology established a standardized 3D ECT-based in vitro testbed for chronic CCM, allowing evaluation of physiological and molecular effects on human cardiac tissues.


Assuntos
Células-Tronco Pluripotentes Induzidas , Contração Miocárdica , Miócitos Cardíacos , Engenharia Tecidual , Humanos , Miócitos Cardíacos/metabolismo , Células Cultivadas , Células-Tronco Pluripotentes Induzidas/metabolismo , Sinalização do Cálcio , Fatores de Tempo , Acoplamento Excitação-Contração , Fibroblastos/metabolismo , Regulação da Expressão Gênica , Terapia por Estimulação Elétrica/instrumentação , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/metabolismo
2.
J Cosmet Dermatol ; 23(5): 1620-1628, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38468421

RESUMO

BACKGROUND: Skin's exposure to intrinsic and extrinsic factors causes age-related changes, leading to a lower amount of dermal collagen and elastin. AIM: This study investigated the effects of a novel facial muscle stimulation technology combined with radiofrequency (RF) heating on dermal collagen and elastin content for the treatment of facial wrinkles and skin laxity. METHODS: The active group subjects (N = 6) received four 20-min facial treatments with simultaneous RF and facial muscle stimulation, once weekly. The control subject (N = 1) was untreated. Skin biopsies obtained at baseline, 1-month and 3-month follow-up were evaluated histologically to determine collagen and elastin fibers content. A group of independent aestheticians evaluated facial skin appearance and wrinkle severity. Patient safety was followed. RESULTS: In the active group, collagen-occupied area reached 11.91 ± 1.80 × 106 µm2 (+25.32%, p < 0.05) and 12.35 ± 1.44 × 105 µm2 (+30.00%, p < 0.05) at 1-month and 3-month follow-up visits. Elastin-occupied area at 1-month and 3-month follow-up was 1.64 ± 0.14 × 105 µm2 (+67.23%, p < 0.05), and 1.99 ± 0.21 × 105 µm2 (+102.80%, p < 0.05). In the control group, there was no significant difference (p > 0.05) in collagen and elastin fibers. Active group wrinkle scores decreased from 5 (moderate, class II) to 3 (mild, class I). All subjects, except the control, improved in appearance posttreatment. No adverse events or side effects occurred. CONCLUSION: Decreased dermal collagen and elastin levels contributes to a gradual decline in skin elasticity, leading to facial wrinkles and unfirm skin. Study results showed noticeable improvement in facial appearance and increased dermal collagen and elastin content subsequent to simultaneous, noninvasive RF, and facial muscle stimulation treatments.


Assuntos
Colágeno , Elastina , Músculos Faciais , Envelhecimento da Pele , Humanos , Elastina/análise , Elastina/metabolismo , Envelhecimento da Pele/efeitos da radiação , Colágeno/metabolismo , Colágeno/análise , Feminino , Pessoa de Meia-Idade , Adulto , Músculos Faciais/efeitos da radiação , Terapia por Radiofrequência/métodos , Terapia por Radiofrequência/efeitos adversos , Masculino , Terapia por Estimulação Elétrica/efeitos adversos , Terapia por Estimulação Elétrica/instrumentação , Terapia por Estimulação Elétrica/métodos , Técnicas Cosméticas/efeitos adversos , Técnicas Cosméticas/instrumentação , Pele/efeitos da radiação , Pele/patologia , Face , Biópsia , Resultado do Tratamento
3.
Int J Surg ; 110(4): 2104-2114, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38329092

RESUMO

OBJECTIVE: Sacral neuromodulation (SNM) has emerged as an effective therapy for refractory lower urinary tract dysfunction (LUTD). Remote programming holds promise in addressing the time and economic burdens associated with outpatient programming, especially for patients in the observation period following Stage I implant surgery (where the lead is implanted first without the pulse generator). The study aimed to explore the effectiveness and patient satisfaction of remote programming for Stage I SNM patients, and analyze the benefits patients gain from remote programming. METHODS: This prospective study was conducted at multiple high-level clinical SNM centres in China. Patients requiring SNM implantation were enroled and divided into two groups based on patient preference: remote programming (RP) group and outpatient control (OC) group. Patient attitudes toward RP were assessed through questionnaires, and the degree of symptom improvement was compared between the two groups to explore the usability of RP. RESULTS: A total of 63 participants from 6 centres were included in the study, with 32 belonging to the RP group. The remote programming system presents a high level of usability (98%) and willingness (satisfaction rate: 96.83%) in result of questionnaire. RP showed a significant advantage in improving patients' score of ICSI/ICPI (medianΔICSI/ICPI RP vs. OC= -13.50 vs -2, P =0.015). And slightly ameliorate urinary symptoms such as pain (medianΔVAS RP vs. OC= -1 vs 0, P = 0.164) and urgency (medianΔOBASS -2.5 vs. -1, P = 0.,229), but the difference was not statistically significant. RP did not significantly impact the quality of life of patients ( P =0.113), so do the rate of phase-two conversion ( P = 0.926) or programming parameters. CONCLUSION: To the best of our knowledge, the presented study is the first multicenter research focusing on the remote programming of Stage I SNM patients. Through the clinical implementation and patient feedback, we demonstrate that remote programming is not inferior to in-person programming in terms of success rate, effectiveness, safety, and patient satisfaction.


Assuntos
Terapia por Estimulação Elétrica , Estudos de Viabilidade , Satisfação do Paciente , Humanos , Estudos Prospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Terapia por Estimulação Elétrica/métodos , Terapia por Estimulação Elétrica/instrumentação , Idoso , Resultado do Tratamento , Inquéritos e Questionários , Plexo Lombossacral , Sintomas do Trato Urinário Inferior/terapia , China , Sacro/inervação
4.
J Neural Eng ; 20(3)2023 06 09.
Artigo em Inglês | MEDLINE | ID: mdl-37224804

RESUMO

One of the ultimate goals of neurostimulation field is to design materials, devices and systems that can simultaneously achieve safe, effective and tether-free operation. For that, understanding the working mechanisms and potential applicability of neurostimulation techniques is important to develop noninvasive, enhanced, and multi-modal control of neural activity. Here, we review direct and transduction-based neurostimulation techniques by discussing their interaction mechanisms with neurons via electrical, mechanical, and thermal means. We show how each technique targets modulation of specific ion channels (e.g. voltage-gated, mechanosensitive, heat-sensitive) by exploiting fundamental wave properties (e.g. interference) or engineering nanomaterial-based systems for efficient energy transduction. Overall, our review provides a detailed mechanistic understanding of neurostimulation techniques together with their applications toin vitro, in vivo, and translational studies to guide the researchers toward developing more advanced systems in terms of noninvasiveness, spatiotemporal resolution, and clinical applicability.


Assuntos
Bioengenharia , Terapia por Estimulação Elétrica , Neurônios , Neurônios/fisiologia , Terapia por Estimulação Elétrica/instrumentação , Terapia por Estimulação Elétrica/métodos
5.
Nature ; 618(7963): 126-133, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37225984

RESUMO

A spinal cord injury interrupts the communication between the brain and the region of the spinal cord that produces walking, leading to paralysis1,2. Here, we restored this communication with a digital bridge between the brain and spinal cord that enabled an individual with chronic tetraplegia to stand and walk naturally in community settings. This brain-spine interface (BSI) consists of fully implanted recording and stimulation systems that establish a direct link between cortical signals3 and the analogue modulation of epidural electrical stimulation targeting the spinal cord regions involved in the production of walking4-6. A highly reliable BSI is calibrated within a few minutes. This reliability has remained stable over one year, including during independent use at home. The participant reports that the BSI enables natural control over the movements of his legs to stand, walk, climb stairs and even traverse complex terrains. Moreover, neurorehabilitation supported by the BSI improved neurological recovery. The participant regained the ability to walk with crutches overground even when the BSI was switched off. This digital bridge establishes a framework to restore natural control of movement after paralysis.


Assuntos
Interfaces Cérebro-Computador , Encéfalo , Terapia por Estimulação Elétrica , Reabilitação Neurológica , Traumatismos da Medula Espinal , Medula Espinal , Caminhada , Humanos , Encéfalo/fisiologia , Terapia por Estimulação Elétrica/instrumentação , Terapia por Estimulação Elétrica/métodos , Quadriplegia/etiologia , Quadriplegia/reabilitação , Quadriplegia/terapia , Reprodutibilidade dos Testes , Medula Espinal/fisiologia , Traumatismos da Medula Espinal/complicações , Traumatismos da Medula Espinal/reabilitação , Traumatismos da Medula Espinal/terapia , Caminhada/fisiologia , Perna (Membro)/fisiologia , Reabilitação Neurológica/instrumentação , Reabilitação Neurológica/métodos , Masculino
6.
Proc Natl Acad Sci U S A ; 119(33): e2203287119, 2022 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-35939711

RESUMO

Electrical neuron stimulation holds promise for treating chronic neurological disorders, including spinal cord injury, epilepsy, and Parkinson's disease. The implementation of ultrathin, flexible electrodes that can offer noninvasive attachment to soft neural tissues is a breakthrough for timely, continuous, programable, and spatial stimulations. With strict flexibility requirements in neural implanted stimulations, the use of conventional thick and bulky packages is no longer applicable, posing major technical issues such as short device lifetime and long-term stability. We introduce herein a concept of long-lived flexible neural electrodes using silicon carbide (SiC) nanomembranes as a faradic interface and thermal oxide thin films as an electrical barrier layer. The SiC nanomembranes were developed using a chemical vapor deposition (CVD) process at the wafer level, and thermal oxide was grown using a high-quality wet oxidation technique. The proposed material developments are highly scalable and compatible with MEMS technologies, facilitating the mass production of long-lived implanted bioelectrodes. Our experimental results showed excellent stability of the SiC/silicon dioxide (SiO2) bioelectronic system that can potentially last for several decades with well-maintained electronic properties in biofluid environments. We demonstrated the capability of the proposed material system for peripheral nerve stimulation in an animal model, showing muscle contraction responses comparable to those of a standard non-implanted nerve stimulation device. The design concept, scalable fabrication approach, and multimodal functionalities of SiC/SiO2 flexible electronics offer an exciting possibility for fundamental neuroscience studies, as well as for neural stimulation-based therapies.


Assuntos
Terapia por Estimulação Elétrica , Neuroestimuladores Implantáveis , Nanoestruturas , Semicondutores , Compostos Inorgânicos de Carbono/química , Terapia por Estimulação Elétrica/instrumentação , Membranas Artificiais , Compostos de Silício/química , Dióxido de Silício/química
7.
Dis Colon Rectum ; 65(2): 284-294, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34990427

RESUMO

BACKGROUND: Changes in anorectal sensation have been reported in patients with fecal incontinence, and there is limited evidence that sacral nerve stimulation can restore normal sensation. OBJECTIVE: The aims of the present study were to investigate changes in the transmission of sensory anorectal stimuli in a rodent model of fecal incontinence and to study the effects of sacral nerve stimulation on defecation behavior. DESIGN: An established model of fecal incontinence was utilized for this study. INTERVENTION: Pudendal nerve stretch and compression were used in 16 adult female Wistar rats and were monitored for 3 weeks: 6 rats received sacral nerve stimulation for 1 week by using an implantable neurostimulator and 10 rats had nonfunctioning "dummy" devices inserted. Five additional rats were sham operated. Anorectal cortical evoked potentials were used as a surrogate marker for anorectal sensory function. MAIN OUTCOME MEASURES: The primary outcomes measured were fecal incontinence index, evoked potential amplitude, and latency. RESULTS: Fifty percent of rats showed behavioral signs of fecal incontinence measured by the Fecal Incontinence Index (>0.20), calculated by using the pellet distribution outside the cage's latrine area. Anorectal evoked potential amplitude was reduced in rats with a Fecal Incontinence Index >0.20 (p = 0.019). The amplitude of forepaw evoked potentials recorded as a control was not different between groups. Chronic sacral nerve stimulation using the fully implantable device and custom rodent lead was safe and stable during this chronic prospective study. Incontinent rats (n = 3) that received sacral nerve stimulation showed an improvement of Fecal Incontinence Index and an increase of evoked potential amplitude to anorectal stimulation compared with the dummy implant controls (n = 5). LIMITATIONS: The main limitation is the small number of animals that received sacral nerve stimulation. CONCLUSIONS: Chronic sacral nerve stimulation is feasible in rats when miniature telemetric devices are used. Behavioral signs of fecal incontinence were positively correlated with the latency of anorectal evoked potentials. See Video Abstract at http://links.lww.com/DCR/B712.RELACIÓN ENTRE LA ACTIVACIÓN CORTICAL EN RESPUESTA A LOS ESTÍMULOS ANORRECTALES Y EL COMPORTAMIENTO DE CONTINENCIA EN RATAS QUE SE COMPORTAN LIBREMENTE ANTES Y DESPUÉS DE LA APLICACIÓN DE ESTIMULACIÓN DEL NERVIO SACRO. ANTECEDENTES: Se han informado cambios en la sensación anorrectal en pacientes con incontinencia fecal y hay evidencia limitada de que la estimulación del nervio sacro puede restaurar la sensación normal. OBJETIVO: Los objetivos del presente estudio fueron investigar los cambios en la transmisión de estímulos anorrectales sensoriales en un modelo de roedor de incontinencia fecal y estudiar los efectos de la estimulación del nervio sacro en la conducta de defecación. DISEO: Un modelo establecido de incontinencia fecal. INTERVENCIN: Se utilizó estiramiento y compresión del nervio pudendo en 16 ratas Wistar hembras adultas y se les realizó un seguimiento durante 3 semanas: seis ratas recibieron estimulación del nervio sacro durante 1 semana utilizando un neuroestimulador implantable y diez ratas tuvieron insertados dispositivos "ficticios" no funcionantes. Se operaron simuladamente cinco ratas adicionales. Los potenciales evocados corticales anorrectales se utilizaron como marcador subrogado de la función sensorial anorrectal. PRINCIPALES MEDIDAS DE RESULTADO: Índice de incontinencia fecal, amplitud de potenciales evocados y latencia. RESULTADOS: El cincuenta por ciento de las ratas mostró signos de comportamiento de incontinencia fecal medidos por el Índice de incontinencia fecal (> 0.20), calculado utilizando la distribución de heces fuera del área de la letrina de la jaula. La amplitud del potencial evocado anorrectal se redujo en ratas con un índice de incontinencia fecal >0.20 (p = 0.019). La amplitud de los potenciales evocados de la pata delantera registrados como control no fue diferente entre los grupos. La estimulación crónica del nervio sacro utilizando un dispositivo totalmente implantable y un cable de roedor personalizado fue segura y estable durante este estudio prospectivo crónico. Las ratas con incontinencia (N = 3) que recibieron estimulación del nervio sacro mostraron una mejora del índice de incontinencia fecal y un aumento de la amplitud del potencial evocado a la estimulación anorrectal en comparación con los controles de implante ficticio (N = 5). LIMITACIONES: La principal limitación es el pequeño número de animales que recibieron estimulación del nervio sacro. CONCLUSIONES: La estimulación crónica del nervio sacro es factible en ratas cuando se utilizan dispositivos telemétricos en miniatura. Los signos conductuales de incontinencia fecal se correlacionaron positivamente con la latencia de los potenciales evocados anorrectales. Consulte Video Resumen en http://links.lww.com/DCR/B712. (Traducción-Dr. Jorge Silva Velazco).


Assuntos
Excitabilidade Cortical/fisiologia , Terapia por Estimulação Elétrica/instrumentação , Comportamento Excretor Animal/fisiologia , Incontinência Fecal/fisiopatologia , Incontinência Fecal/terapia , Nervos Espinhais , Animais , Modelos Animais de Doenças , Incontinência Fecal/psicologia , Feminino , Neuroestimuladores Implantáveis , Ratos , Ratos Wistar
8.
Nat Commun ; 13(1): 513, 2022 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-35082313

RESUMO

Loss of photoreceptors in atrophic age-related macular degeneration (AMD) results in severe visual impairment. Since the low-resolution peripheral vision is retained in such conditions, restoration of central vision should not jeopardize the surrounding healthy retina and allow for simultaneous use of the natural and prosthetic sight. This interim report, prespecified in the study protocol, presents the first clinical results with a photovoltaic substitute of the photoreceptors providing simultaneous use of the central prosthetic and peripheral natural vision in atrophic AMD. In this open-label single group feasibility trial (NCT03333954, recruitment completed), five patients with geographic atrophy have been implanted with a wireless 2 x 2 mm-wide 30 µm-thick device, having 378 pixels of 100 µm in size. All 5 patients achieved the primary outcome of the study by demonstrating the prosthetic visual perception in the former scotoma. The four patients with a subretinal placement of the chip demonstrated the secondary outcome: Landolt acuity of 1.17 ± 0.13 pixels, corresponding to the Snellen range of 20/460-20/565. With electronic magnification of up to a factor of 8, patients demonstrated prosthetic acuity in the range of 20/63-20/98. Under room lighting conditions, patients could simultaneously use prosthetic central vision and their remaining peripheral vision in the implanted eye and in the fellow eye.


Assuntos
Terapia por Estimulação Elétrica/instrumentação , Terapia por Estimulação Elétrica/métodos , Atrofia Geográfica/terapia , Degeneração Macular/terapia , Transtornos da Visão/terapia , Percepção Visual , Próteses Visuais , Idoso , Idoso de 80 Anos ou mais , Estimulação Elétrica , Desenho de Equipamento , Óculos , Humanos , Retina , Resultado do Tratamento , Acuidade Visual
9.
Ann Otol Rhinol Laryngol ; 131(4): 365-372, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34096343

RESUMO

OBJECTIVES: Facial paralysis is a debilitating condition with substantial functional and psychological consequences. This feline-model study evaluates whether facial muscles can be selectively activated in acute and chronic implantation of 16-channel multichannel cuff electrodes (MCE). METHODS: Two cats underwent acute terminal MCE implantation experiments, 2 underwent chronic MCE implantation in uninjured facial nerves (FN) and tested for 6 months, and 2 underwent chronic MCE implantation experiments after FN transection injury and tested for 3 months. The MCE were wrapped around the main trunk of the skeletonized FN, and data collection consisted of EMG thresholds, amplitudes, and selectivity of muscle activation. RESULTS: In acute experimentation, activation of specific channels (ie, channels 1-3 and 6-8) resulted in selective activation of orbicularis oculi, whereas activation of other channels (ie, channels 4, 5, or 8) led to selective activation of levator auris longus with higher EMG amplitudes. MCE implantation yielded stable and selective facial muscle activation EMG thresholds and amplitudes up to a 5-month period. Modest selective muscle activation was furthermore obtained after a complete transection-reapproximating nerve injury after a 3-month recovery period and implantation reoperation. Chronic implantation of MCE did not lead to fibrosis on histology. Field steering was achieved to activate distinct facial muscles by sending simultaneous subthreshold currents to multiple channels, thus theoretically protecting against nerve damage from chronic electrical stimulation. CONCLUSION: Our proof-of-concept results show the ability of an MCE, supplemented with field steering, to provide a degree of selective facial muscle stimulation in a feline model, even following nerve regeneration after FN injury. LEVEL OF EVIDENCE: N/A.


Assuntos
Terapia por Estimulação Elétrica/instrumentação , Eletrodos Implantados , Músculos Faciais/inervação , Músculos Faciais/fisiopatologia , Traumatismos do Nervo Facial/complicações , Paralisia Facial/terapia , Contração Muscular/fisiologia , Animais , Gatos , Modelos Animais de Doenças , Eletromiografia , Traumatismos do Nervo Facial/fisiopatologia , Paralisia Facial/etiologia , Paralisia Facial/fisiopatologia , Feminino
10.
BMC Pulm Med ; 21(1): 314, 2021 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-34625059

RESUMO

BACKGROUND: Diaphragm atrophy and dysfunction is a major problem among critically ill patients on mechanical ventilation. Ventilator-induced diaphragmatic dysfunction is thought to play a major role, resulting in a failure of weaning. Stimulation of the phrenic nerves and resulting diaphragm contraction could potentially prevent or treat this atrophy. The subject of this study is to determine the effectiveness of diaphragm stimulation in preventing atrophy by measuring changes in its thickness. METHODS: A total of 12 patients in the intervention group and 10 patients in the control group were enrolled. Diaphragm thickness was measured by ultrasound in both groups at the beginning of study enrollment (hour 0), after 24 hours, and at study completion (hour 48). The obtained data were then statistically analyzed and both groups were compared. RESULTS: The results showed that the baseline diaphragm thickness in the interventional group was (1.98 ± 0.52) mm and after 48 hours of phrenic nerve stimulation increased to (2.20 ± 0.45) mm (p=0.001). The baseline diaphragm thickness of (2.00 ± 0.33) mm decreased in the control group after 48 hours of mechanical ventilation to (1.72 ± 0.20) mm (p<0.001). CONCLUSIONS: Our study demonstrates that induced contraction of the diaphragm by pacing the phrenic nerve not only reduces the rate of its atrophy during mechanical ventilation but also leads to an increase in its thickness - the main determinant of the muscle strength required for spontaneous ventilation and successful ventilator weaning. TRIAL REGISTRATION: The study was registered with ClinicalTrials.gov (18/06/2018, NCT03559933, https://clinicaltrials.gov/ct2/show/NCT03559933 ).


Assuntos
Diafragma/fisiopatologia , Terapia por Estimulação Elétrica/métodos , Nervo Frênico/fisiologia , Respiração Artificial/efeitos adversos , Insuficiência Respiratória/terapia , Idoso , Estado Terminal , Diafragma/diagnóstico por imagem , Terapia por Estimulação Elétrica/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Atrofia Muscular/etiologia , Atrofia Muscular/fisiopatologia , Estudos Prospectivos , Respiração Artificial/métodos , Ultrassonografia
11.
Laryngoscope ; 131(11): 2616-2624, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34626128

RESUMO

OBJECTIVES/HYPOTHESIS: To provide the ADHERE registry Upper Airway Stimulation (UAS) outcomes update, including analyses grouped by body mass index (BMI) and therapy discomfort. STUDY DESIGN: Prospective observational study. METHODS: ADHERE captures UAS outcomes including apnea-hypopnea index (AHI), Epworth sleepiness scale (ESS), therapy usage, patient satisfaction, clinician assessment, and safety over a 1-year period. BMI ≤32 kg/m2 (BMI32 ) and 32 < BMI ≤35 kg/m2 (BMI35 ) group outcomes were examined. RESULTS: One thousand eight hundred forty-nine patients enrolled in ADHERE, 1,019 reached final visit, 843 completed the visit. Significant changes in AHI (-20.9, P < .0001) and ESS (- 4.4, P < .0001) were demonstrated. Mean therapy usage was 5.6 ± 2.2 hr/day. Significant therapy use difference was present in patients with reported discomfort versus no discomfort (4.9 ± 2.5 vs. 5.7 ± 2.1 hr/day, P = .01). Patients with discomfort had higher final visit mean AHI versus without discomfort (18.9 ± 18.5 vs. 13.5 ± 13.7 events/hr, P = .01). Changes in AHI and ESS were not significantly different. Serious adverse events reported in 2.3% of patients. Device revision rate was 1.9%. Surgical success was less likely in BMI35 versus BMI32 patients (59.8% vs. 72.2%, P = .02). There was a significant therapy use difference: 5.8 ± 2.0 hr/day in BMI32 versus 5.2 ± 2.2 hr/day in BMI35 (P = .028). CONCLUSIONS: Data from ADHERE demonstrate high efficacy rates for UAS. Although surgical response rate differs between BMI32 and BMI35 patient groups, the AHI and ESS reduction is similar. Discomfort affects therapy adherence and efficacy. Thus, proper therapy settings adjustment to ensure comfort is imperative to improve outcomes. LEVEL OF EVIDENCE: 4 Laryngoscope, 131:2616-2624, 2021.


Assuntos
Índice de Massa Corporal , Terapia por Estimulação Elétrica/efeitos adversos , Neuroestimuladores Implantáveis/efeitos adversos , Cooperação do Paciente/estatística & dados numéricos , Apneia Obstrutiva do Sono/terapia , Idoso , Terapia por Estimulação Elétrica/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros/estatística & dados numéricos , Índice de Gravidade de Doença , Apneia Obstrutiva do Sono/diagnóstico , Resultado do Tratamento
13.
Bull Exp Biol Med ; 171(3): 379-383, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34292446

RESUMO

This article discusses the contribution of fMRI- and fMRI-EEG-neurofeedback into recovery of motor function in two subacute stroke patients during the early post-stroke period. Premotor and supplementary motor zones of the cortex were chosen as the targets of voluntary control. Patient 1 received 6 sessions of motor imagery-based fMRI neurofeedback of secondary motor areas activity and Patient 2 received a similar course with the addition of µ- and ß-EEG activity suppression. Both reduced the motor deficit severity, improved on the quality of life, and increased the C3/C4 coherence to other central leads within EEG µ-band. Patient 1 reliably increased the fMRI signal in target areas and improved on the strength and speed of hand movements. Patient 2 (fMRI-EEG) mastered the EEG activity regulation to a greater degree. The authors conclude that pure fMRI neurofeedback and bi-modal fMRI-EEG neurofeedback produce different clinical effects in motor rehabilitation, which confirms the prospect of the closed-loop stroke treatment.


Assuntos
Imagens, Psicoterapia/métodos , Córtex Motor/fisiopatologia , Neurorretroalimentação/métodos , Reabilitação do Acidente Vascular Cerebral/métodos , Acidente Vascular Cerebral/terapia , Terapia por Estimulação Elétrica/instrumentação , Terapia por Estimulação Elétrica/métodos , Eletroencefalografia , Força da Mão/fisiologia , Humanos , Imagens, Psicoterapia/instrumentação , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Córtex Motor/diagnóstico por imagem , Neurorretroalimentação/instrumentação , Desempenho Psicomotor/fisiologia , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/fisiopatologia , Reabilitação do Acidente Vascular Cerebral/instrumentação , Estimulação Magnética Transcraniana/instrumentação , Estimulação Magnética Transcraniana/métodos , Resultado do Tratamento
14.
Proc Natl Acad Sci U S A ; 118(28)2021 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-34260393

RESUMO

Electrostimulation has been recognized as a promising nonpharmacological treatment in orthopedics to promote bone fracture healing. However, clinical applications have been largely limited by the complexity of equipment operation and stimulation implementation. Here, we present a self-powered implantable and bioresorbable bone fracture electrostimulation device, which consists of a triboelectric nanogenerator for electricity generation and a pair of dressing electrodes for applying electrostimulations directly toward the fracture. The device can be attached to irregular tissue surfaces and provide biphasic electric pulses in response to nearby body movements. We demonstrated the operation of this device on rats and achieved effective bone fracture healing in as short as 6 wk versus the controls for more than 10 wk to reach the same healing result. The optimized electrical field could activate relevant growth factors to regulate bone microenvironment for promoting bone formation and bone remodeling to accelerate bone regeneration and maturation, with statistically significant 27% and 83% improvement over the control groups in mineral density and flexural strength, respectively. This work provided an effective implantable fracture therapy device that is self-responsive, battery free, and requires no surgical removal after fulfilling the biomedical intervention.


Assuntos
Implantes Absorvíveis , Biorretroalimentação Psicológica , Fontes de Energia Elétrica , Terapia por Estimulação Elétrica/instrumentação , Consolidação da Fratura , Fraturas Ósseas/terapia , Animais , Eletricidade , Desenho de Equipamento , Ratos , Padrões de Referência
16.
Urology ; 157: 71-78, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34048826

RESUMO

OBJECTIVES: To evaluate the safety and efficacy of the eCoin - a nickel-sized, primary battery-powered, neuromodulation device for the treatment of urgency urinary incontinence which is implanted in the lower leg in a 20-minute procedure under local anesthesia. A feasibility clinical trial was conducted and the results after 1 year of treatment with the eCoin are presented. METHODS: A total of 46 participants with refractory urgency urinary incontinence were included in this prospective, single-arm, open-label study. This study was conducted at 7 sites in the United States and New Zealand. Participants in this study were implanted with the eCoin in the lower leg over the tibial nerve and activated after 4 weeks. Bladder diary data and validated quality-of-life instruments, collected at 3, 6, and 12 months' post-activation, were compared to baseline values. RESULTS: Responders were defined as those who had a ≥50% reduction in reported episodes of urgency urinary incontinence. At 12 months', 65% of participants were considered responders with 26% of participants achieving complete continence. The median number of urgency urinary incontinence episodes per day decreased from 4.2 at baseline to 1.7 at 12 months'. Seventy percent of participants reported feeling "better", "much better", or "very much better" on the Likert 7-point maximum scale. One participant experienced a related serious adverse event. CONCLUSION: The eCoin is a safe and effective treatment for urgency urinary incontinence associated with overactive bladder syndrome, with significant reduction or complete resolution of symptoms and no significant safety concerns.


Assuntos
Terapia por Estimulação Elétrica/instrumentação , Neuroestimuladores Implantáveis , Bexiga Urinária Hiperativa/complicações , Incontinência Urinária de Urgência/terapia , Terapia por Estimulação Elétrica/efeitos adversos , Desenho de Equipamento/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Neuroestimuladores Implantáveis/efeitos adversos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Implantação de Prótese , Qualidade de Vida , Autorrelato , Nervo Tibial , Fatores de Tempo , Resultado do Tratamento , Incontinência Urinária de Urgência/etiologia
17.
J Neuroeng Rehabil ; 18(1): 87, 2021 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-34034762

RESUMO

BACKGROUND: Despite important advancements in control and mechatronics of myoelectric prostheses, the communication between the user and his/her bionic limb is still unidirectional, as these systems do not provide somatosensory feedback. Electrotactile stimulation is an attractive technology to close the control loop since it allows flexible modulation of multiple parameters and compact interface design via multi-pad electrodes. However, the stimulation interferes with the recording of myoelectric signals and this can be detrimental to control. METHODS: We present a novel compact solution for simultaneous recording and stimulation through dynamic blanking of stimulation artefacts. To test the system, a feedback coding scheme communicating wrist rotation and hand aperture was developed specifically to stress the myoelectric control while still providing meaningful information to the subjects. Ten subjects participated in an experiment, where the quality of closed-loop myoelectric control was assessed by controlling a cursor in a two degrees of freedom target-reaching task. The benchmark performance with visual feedback was compared to that achieved by combining visual feedback and electrotactile stimulation as well as by using electrotactile feedback only. RESULTS: There was no significant difference in performance between visual and combined feedback condition with regards to successfully reached targets, time to reach a target, path efficiency and the number of overshoots. Therefore, the quality of myoelectric control was preserved in spite of the stimulation. As expected, the tactile condition was significantly poorer in completion rate (100/4% and 78/25% for combined and tactile condition, respectively) and time to reach a target (9/2 s and 13/4 s for combined and tactile condition, respectively). However, the performance in the tactile condition was still good, with no significant difference in path efficiency (38/8%) and the number of overshoots (0.5/0.4 overshoots), indicating that the stimulation was meaningful for the subjects and useful for closed-loop control. CONCLUSIONS: Overall, the results demonstrated that the developed system can provide robust closed-loop control using electrotactile stimulation. The system supports different encoding schemes and allows placing the recording and stimulation electrodes next to each other. This is an important step towards an integrated solution where the developed unit will be embedded into a prosthetic socket.


Assuntos
Algoritmos , Artefatos , Membros Artificiais , Desenho de Prótese , Interface Usuário-Computador , Adulto , Terapia por Estimulação Elétrica/instrumentação , Terapia por Estimulação Elétrica/métodos , Eletromiografia/métodos , Retroalimentação Sensorial/fisiologia , Feminino , Humanos , Masculino , Tato/fisiologia
18.
J Urol ; 206(2): 399-408, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33797291

RESUMO

PURPOSE: A novel leadless tibial nerve stimulator provides a primary battery-powered, coin-sized, minimally invasive option to deliver automatic low-duty cycle stimulation for overactive bladder syndrome therapy. A pivotal trial was conducted to evaluate the safety and efficacy of this investigational device, eCoin®, for treating refractory urgency urinary incontinence. MATERIALS AND METHODS: This was a prospective, open-label, single arm trial carried out at 15 U.S. medical centers involving 137 subjects with refractory urgency urinary incontinence. After implantation in the lower leg above the fascia over the tibial nerve, eCoin delivered automated stimulation sessions for the duration of the study. The primary efficacy measure was the proportion of subjects who achieved a 50% or greater reduction from baseline in urgency urinary incontinence episodes after 48 weeks of therapy. The primary safety measure was device-related adverse events at the same time point. RESULTS: Of 137 subjects enrolled, 133 were implanted with eCoin, and 132 were included in the intention-to-treat population. Of those 132 subjects, 98% were female, mean±SD age was 63.9±10.9 years, and baseline daily urgency urinary incontinence episodes were 4.3±3.1. The primary efficacy analysis showed 68% (95% CI: 60%-76%) of subjects experienced at least a 50% reduction in urgency urinary incontinence episodes at 48 weeks post-activation; 16% of implanted subjects experienced device-related events through 52 weeks post-implantation. CONCLUSIONS: eCoin demonstrated clinical benefit for treating overactive bladder syndrome with automatic delivery of an intermittent low-duty cycle and implanted with a minimally invasive, brief procedure.


Assuntos
Terapia por Estimulação Elétrica/instrumentação , Nervo Tibial , Incontinência Urinária de Urgência/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Prospectivos
19.
Muscle Nerve ; 64(1): 86-89, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33822375

RESUMO

INTRODUCTION/AIMS: The virtual cathode (VC) is a site near the anode where the nerve can be stimulated. Costimulation of neighboring nerves via the VC can affect recording and interpretation of responses. Hence, it is important to teach trainees the concept of the VC. The VC has been demonstrated previously with subtle changes in response latency, amplitude, and shape. Herein we describe an experiment that simply demonstrates a VC with its effects recognizable by gross changes in waveforms. METHODS: Compound muscle action potentials of the abductor pollicis brevis were recorded using various placements of the cathode and anode at different stimulus intensity levels. Studies were performed in nine healthy subjects. RESULTS: Three patterns were observed that demonstrated no stimulation, partial stimulation, and complete nerve stimulation by the VC. Partial stimulation yielded responses with long duration and low amplitude. Response patterns also depended on stimulus strength and proximity of the nerve from the skin surface. DISCUSSION: This experiment demonstrates that nerve stimulation can occur near the anode when high-intensity stimulus is used. It also illustrates collision of action potentials. This exercise can help trainees understand potential pitfalls in nerve conduction studies, especially at very proximal stimulation sites or when high stimulus intensity is used.


Assuntos
Competência Clínica , Terapia por Estimulação Elétrica/instrumentação , Terapia por Estimulação Elétrica/métodos , Nervo Mediano/fisiologia , Condução Nervosa/fisiologia , Potenciais de Ação/fisiologia , Adulto , Idoso , Eletrodos , Eletromiografia/instrumentação , Eletromiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/inervação , Músculo Esquelético/fisiologia , Exame Neurológico/instrumentação , Exame Neurológico/métodos
20.
Nutr Metab Cardiovasc Dis ; 31(5): 1635-1644, 2021 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-33812737

RESUMO

BACKGROUND AND AIM: Our previous study found carotid baroreceptor stimulation (CBS) reduces body weight and white adipose tissue (WAT) weight, restores abnormal secretion of adipocytokines and inflammation factors, decreases systolic blood pressure (SBP) by inhibiting activation of sympathetic nervous system (SNS) and renin-angiotensin system (RAS) in obese rats. In this study, we explore effects of CBS on aortic remodeling in obese rats. METHODS AND RESULTS: Rats were fed high-fat diet (HFD) for 16 weeks to induce obesity and underwent either CBS device implantation and stimulation or sham operation at 8 weeks. BP and body weight were measured weekly. RAS activity of WAT, histological, biochemical and functional profiles of aortas were detected after 16 weeks. CBS effectively decreased BP in obese rats, downregulated mRNA expression of angiotensinogen (AGT) and renin in WAT, concentrations of AGT, renin, angiotensin II (Ang II), protein levels of Ang II receptor 1 (AT1R) and Ang II receptor 2 (AT2R) in WAT were declined. CBS inhibited reactive oxygen species (ROS) generation, inflammatory response and endoplasmic reticulum (ER) stress in aortas of obese rats, restrained vascular wall thickening and vascular smooth muscle cells (VSMCs) phenotypic switching, increased nitric oxide (NO) synthesis, promoted endothelium-dependent vasodilatation by decreasing protein expression of AT1R and leptin receptor (LepR), increasing protein expression of adiponectin receptor 1 (AdipoR1) in aortic VSMCs. CONCLUSION: CBS reduced BP and reversed aortic remodeling in obese rats, the underlying mechanism might be related to the suppressed SNS activity, restored adipocytokine secretion and restrained RAS activity of WAT.


Assuntos
Tecido Adiposo Branco/metabolismo , Terapia por Estimulação Elétrica , Músculo Liso Vascular/patologia , Obesidade/terapia , Pressorreceptores/fisiopatologia , Sistema Renina-Angiotensina , Remodelação Vascular , Adipocinas/metabolismo , Animais , Aorta Torácica/metabolismo , Aorta Torácica/patologia , Aorta Torácica/fisiopatologia , Pressão Arterial , Modelos Animais de Doenças , Terapia por Estimulação Elétrica/instrumentação , Células Endoteliais/metabolismo , Células Endoteliais/patologia , Neuroestimuladores Implantáveis , Masculino , Músculo Liso Vascular/metabolismo , Músculo Liso Vascular/fisiopatologia , Miócitos de Músculo Liso/metabolismo , Miócitos de Músculo Liso/patologia , Obesidade/metabolismo , Obesidade/patologia , Obesidade/fisiopatologia , Ratos Sprague-Dawley , Receptor Tipo 1 de Angiotensina/metabolismo , Receptores de Adiponectina , Receptores para Leptina/metabolismo , Vasodilatação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...